Flexible
cables >> 60227 IEC
56
Heat-resistant
light PVC-sheathed cord for a maximum conductor temperature of 90°C.
Application:
- For installation in domestic environment, for domestic household
apparatus, lamps office machines with light mechanical stress. Suitable
for environments where higher temperature resistance is needed,
if cable is not in direct contact with hot surfaces. Not for external
use.
- Minimum bending radius: 6 times of maximum overall diameter.
Standard:
- ISIRI (607)56
- IEC (60227)56
- H03V2V2-F , H03V2V2H2-F
Construction:
- Annealed stranded copper conductor, class 5.
- PVC insulation, type E.
- Cores twisted together for circular cords or laid parallel for
flat cords.
- PVC sheath type ST 10.
General
specification:
- Rated voltage: 300/300 V.
- Working temperature: Max. 90°C.
|
Cross-
sectional
area
Nom.
|
No.
of
wires x
diameter
Nom.
|
Insulation
thickness
Nom.
|
Sheath
thickness Nom.
|
Mean
overall
diameter
|
Insulation
resistance
at 70°C
Min.
|
Weight
Nom.
|
|
Lower
limit
|
Upper
limit
|
|
mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
|
kg/km
|
|
2
x 0.5
|
16
x 0.20
|
0.5
|
0.6
|
4.6
or
3.0 x 4.9
|
5.9
or
3.7 x 5.9
|
0.012
|
35
27
|
|
2
x 0.75
|
24
x 0.20
|
0.5
|
0.6
|
4.9
or
3.2 x 5.2
|
6.3
or
3.8 x 6.3
|
0.010
|
43
33
|
|
3
x 0.5
|
16
x 0.20
|
0.5
|
0.6
|
4.9
|
6.3
|
0.012
|
40
|
|
3
x 0.75
|
24
x 0.20
|
0.5
|
0.6
|
5.2
|
6.7
|
0.010
|
51
|
|