Flexible cables >> 60227 IEC 56

Heat-resistant light PVC-sheathed cord for a maximum conductor temperature of 90°C.

Application:
- For installation in domestic environment, for domestic household apparatus, lamps office machines with light mechanical stress. Suitable for environments where higher temperature resistance is needed, if cable is not in direct contact with hot surfaces. Not for external use.
- Minimum bending radius: 6 times of maximum overall diameter.

Standard:
- ISIRI (607)56
- IEC (60227)56
- H03V2V2-F , H03V2V2H2-F

Construction:
- Annealed stranded copper conductor, class 5.
- PVC insulation, type E.
- Cores twisted together for circular cords or laid parallel for flat cords.
- PVC sheath type ST 10.

General specification:
- Rated voltage: 300/300 V.
- Working temperature: Max. 90°C.

Cross-
sectional
area
Nom.
No. of
wires x
diameter
Nom.
Insulation
thickness
Nom.
Sheath thickness Nom.
Mean overall
diameter
Insulation
resistance
at 70°C
Min.
Weight
Nom.
Lower limit
Upper limit
mm2
mm
mm
mm
mm
mm
kg/km
2 x 0.5
16 x 0.20
0.5
0.6
4.6
or
3.0 x 4.9
5.9
or
3.7 x 5.9
0.012
35

27
2 x 0.75
24 x 0.20
0.5
0.6
4.9
or
3.2 x 5.2
6.3
or
3.8 x 6.3
0.010
43

33
3 x 0.5
16 x 0.20
0.5
0.6
4.9
6.3
0.012
40
3 x 0.75
24 x 0.20
0.5
0.6
5.2
6.7
0.010
51