Flexible cables >> 60227 IEC 53

Ordinary PVC-sheathed cord.

Application:
- For all applications where cables undergo medium mechanical stress as in small and medium apparatus in domestic, commercial or light industrial environment (e.g. household appliances such as washing-machines, sewing-machines and fridges). The temporary or occasional use outdoor place where vertical water drops fall is likely allowed. Not suitable for use in industrial or agricultural workshops, connection of portable and non-domestic tools.
- Minimum bending radius: 10 times of maximum overall diameter for mobile service and 4 times of maximum overall diameter for fixed installation.

Standard:
- ISIRI (607)53
- IEC (60227)53
- H05VVF , H05VVH2-F

Construction:
- Annealed stranded copper conductor, class 5.
- PVC insulation, type D.
- Cores twisted together for circular cords or laid parallel for flat cords.
- PVC sheath type ST 5.

General specification:
- Rated voltage: 300/500 V.
- Working temperature: Max. 70°C.

Cross-
sectional
area
Nom.
No. of
wires x
diameter
Nom.
Insulation
thickness
Nom.
Sheath thickness Nom.
Mean overall
diameter
Insulation
resistance
at 70°C
Min.
Weight
Nom.
Lower limit
Upper limit
mm2
mm
mm
mm
mm
mm
kg/km
2 x 0.75
24 x 0.20
0.6
0.8
57
or
3.7 x 6.0
7.2
or
4.5 x 7.2
0.011
53

45
2 x 1
32 x 0.20
0.6
0.8
5.9
7.5
0.010
63
2 x 1.5
30 x 0.25
0.7
0.8
6.8
8.6
0.010
82
2 x 2.5
56 x 0.25
0.8
1.0
8.4
10.6
0.009
129
3 x 0.75
24 x 0.20
0.6
0.8
6.0
7.6
0.011
67
3 x 1
32 x 0.20
0.6
0.8
6.3
8.0
0.010
75
3 x 1.5
30 x 0.25
0.7
0.9
7.4
9.4
0.010
105
3 x 2.5
56 x 0.25
0.8
1.1
9.2
11.4
0.009
164
4 x 0.75
24 x 0.20
0.6
0.8
6.6
8.3
0.011
77
4 x 1
32 x 0.20
0.6
0.9
7.1
9.0
0.010
94
4 x 1.5
30 x 0.25
0.7
1.0
8.4
10.5
0.010
135
4 x 2.5
56 x 0.25
0.8
1.1
10.1
12.5
0.009
201
5 x 0.75
24 x 0.20
0.6
0.9
7.4
9.3
0.011
96
5 x 1
32 x 0.20
0.6
0.9
7.8
9.8
0.010
112
5 x 1.5
30 x 0.25
0.7
1.1
9.3
11.6
0.010
165
5 x 2.5
56 x 0.25
0.8
1.2
11.2
13.9
0.009
245