Flexible
cables >> 60227 IEC
52
Light
PVC sheathed cord.
Application:
- For industrial in domestic environment, offices and shops, for
connecting of light portable apparatus with light mechanical stress
(lamps, office machines, hair dryers, etc.). Not suitable for kitchen
or heating equipments, external use, industrial or agricultural
buildings non for portable, non-domestic tools.
- Minimum bending radius: 6 times of maximum overall diameter.
|
Standard:
- ISIRI (607)52
- IEC (60227)52
- H03VV-F , H03VVH2-F
Construction:
- Annealed stranded copper conductor, class 5.
- PVC insulation, type D.
- Cores twisted together for circular cords or laid parallel
for flat cords.
- PVC sheath type ST 5.
|
 |
General
specification:
- Rated voltage: 300/300 V.
- Working temperature: Max. 70°C.
|
Cross-
sectional
area
Nom.
|
No.
of
wires x
diameter
Nom.
|
Insulation
thickness
Nom.
|
Sheath
thickness
Nom.
|
Mean
overall
diameter
|
Insulation
resistance
at 70°C
Min.
|
Weight
Nom.
|
|
Lower
limit
|
Upper
limit
|
|
mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
|
kg/km
|
|
2
x 0.5
|
16
x 0.20
|
0.5
|
0.6
|
4.6
or
3.0 x 4.9
|
5.9
or
3.7 x 5.9
|
0.012
|
43
35
|
|
2
x 0.75
|
24
x 0.20
|
0.5
|
0.6
|
4.9
or
3.2 x 5.2
|
6.3
or
3.8 x 6.3
|
0.010
|
50
40
|
|
3
x 0.5
|
16
x 0.20
|
0.5
|
0.6
|
4.9
|
6.3
|
0.012
|
51
|
|
3
x 0.75
|
24
x 0.20
|
0.5
|
0.6
|
5.2
|
6.7
|
0.010
|
67
|
|