Flexible cables >> 60227 IEC 52

Light PVC sheathed cord.

Application:
- For industrial in domestic environment, offices and shops, for connecting of light portable apparatus with light mechanical stress (lamps, office machines, hair dryers, etc.). Not suitable for kitchen or heating equipments, external use, industrial or agricultural buildings non for portable, non-domestic tools.
- Minimum bending radius: 6 times of maximum overall diameter.

Standard:
- ISIRI (607)52
- IEC (60227)52
- H03VV-F , H03VVH2-F

Construction:
- Annealed stranded copper conductor, class 5.
- PVC insulation, type D.
- Cores twisted together for circular cords or laid parallel for flat cords.
- PVC sheath type ST 5.

General specification:
- Rated voltage: 300/300 V.
- Working temperature: Max. 70°C.

Cross-
sectional
area
Nom.
No. of
wires x
diameter
Nom.
Insulation
thickness
Nom.
Sheath
thickness
Nom.
Mean overall
diameter
Insulation
resistance
at 70°C
Min.
Weight
Nom.
Lower limit
Upper limit
mm2
mm
mm
mm
mm
mm
kg/km
2 x 0.5
16 x 0.20
0.5
0.6
4.6
or
3.0 x 4.9
5.9
or
3.7 x 5.9

0.012

43

35
2 x 0.75
24 x 0.20
0.5
0.6
4.9
or
3.2 x 5.2
6.3
or
3.8 x 6.3
0.010
50

40
3 x 0.5
16 x 0.20
0.5
0.6
4.9
6.3
0.012
51
3 x 0.75
24 x 0.20
0.5
0.6
5.2
6.7
0.010
67