Flexible cables
>> 60227 IEC 42
Flat non-sheathed cord.
Application:
In dry rooms connecting portable appliances where mechanical stresses are low, not for heating appliances.
Standard:
- ISIRI (607)42
- IEC (60227)42
- H03VH-H
Construction:
- Annealed stranded copper conductor, class 6.
- PVC insulation, type D.
General specification:
- Rated voltage: 300/300 V.
- Working temperature: Max. 70°C.
Cross-
sectional
area
Nom.
No. of
wires x
diameter
Nom.
Insulation
thickness
Nom.
Mean overall
diameter
Insulation
resistance
at 70°C
Min.
Weight
Nom.
Lower limit
Upper limit
mm
2
mm
mm
mm
mm
kg/km
2 x 0.5
28 x 0.15
0.8
2.4 x 4.9
3.0 x 5.9
0.016
23
2 x 0.75
42 x 0.15
0.8
2.6 x 5.2
3.1 x 6.3
0.014
27